MIL-R-22827E
3.6.10 Casters. When specified (see 6.1), casters shall he furnished.
When casters are specified, two rigid and two swivel all steel casters
conforming to MS 24380 and MIL-C-7474 shall be furnished for each container.
The casters shall be constructed to withstand a static load of not less than
welded to the bottom of the container so that the casters will clear top of
fenders on hoist-haul mechanism when the container is in the haul position.
The spacers shall be positioned to center on the supporting members of the
hoist-haul mechanism. The casters shall be suitably located to clear the
container rest members of the hoist-haul assembly when the container is in the
haul position.
3.7 Performance.
In addition to other design and operational requirements
specified herein, all containers shall be capable of withstanding tests
specified in 4.4 without overturning, failure, breakage, or permanent
distortion of any part. The test loads for each size container shall be as
specified in table III.
TABLE III.
Test loads.
3.8 Cleaning, treatment, and paintinq. Surfaces normally painted in good
commercial practice shall be cleaned, treated, and painted as specified
herein. The color of the finish coat shall be as specified (see 6.1).
Surfaces to be painted shall be cleaned and dried to insure that they are free
from contaminants such as oil, grease, welding slag and spatter, loose mill
scale, water, dirt, corrosion product, or any other contaminating substances.
As soon as practicable after cleaning, and before any corrosion product or
other contamination can result, the surfaces shall be prepared or treated to
insure the adhesion of the coating system. The painting shall consist of at
least one coat of primer and one finish coat. The primer shall be applied to
a clean, dry surface as soon as practicable after cleaning and treating.
Painting shall be with manufacturer's current materials according to
manufacturer's current processes and the total dry film thickness shall be not
less than 2.5 mils over the entire surface. The paint shall be free from
runs, sags, orange peel, or other defects.
3.9 Stability.
The containers shall be stable and be in accordance with
ANSI 1245.3.